Split czy monoblok? Czego pompa ciepła wymaga od Twojej instalacji

In the W previous article about heating costs, we compared the costs of different heat sources, and heat pumps came out very well, especially ground-source models. If you’ve already made your decision and are choosing an air-to-water heat pump, you face a second question, just as important as the heat source itself: split or monoblock? This isn’t a cosmetic question about where the unit is located. It’s a question of what the entire system will require of you before it even starts heating.

Split or monoblock: a more important difference than the location of the unit

The most common misconception is that a split has something inside the home, while a monoblock has everything outside. That’s true, but it’s not the most important difference. The key question is different: where is the refrigerant, the substance circulating in the system that actually transfers heat from the air to the water? In a W split system, the refrigerant flows through pipes between the outdoor and indoor units, so some of it is inside the home. In a W monoblock, the entire refrigerant circuit is factory-sealed in a single outdoor casing, and only water enters the home. This seemingly minor design difference can have significant legal consequences that few people are aware of.

Split: the standard that still dominates the market

In a W split system, the outdoor unit contains the compressor and a heat exchanger that draws heat from the air, while the entire hydraulic system—that is, the circulation pump, any buffer tank and the backup heater—is housed in a compact indoor unit. So a refrigerant pipe runs into the home, while all the system water stays inside and never goes outdoors. Contrary to the assumption that monoblocks, which are simpler to install, are replacing older split systems, industry data show the opposite: according to the Polish Organization for the Development of Heat Pump Technology, in the first half of 2026, splits sold about three times as often as monoblocks in Poland, accounting for nearly eighty percent of the market.

The real advantage of a split comes from the fact that the system water never leaves the heated home: no section is exposed to freezing temperatures, so unlike a monoblock, a split does not require additional frost protection. A split can also be a more practical choice for higher heating capacities, where the indoor unit can additionally serve as an integrated buffer tank or provide support for domestic hot water without adding separate components. The price of this flexibility is the bureaucracy described below: since refrigerant actually flows through the home, the law treats it more cautiously.

Monobloc: less paperwork, more work outdoors

A monobloc reverses this arrangement. The entire refrigerant circuit, including the compressor and heat exchanger, is factory-sealed inside a single unit installed outside the building. Only hot water enters the house, as with a traditional boiler. This means the most paperwork-intensive part of the installation, working with the refrigerant, is done once at the factory, and the installer only has to make the simpler hydraulic connection on site. This shortens installation time and can be cheaper, but it comes at a price: since all the system water passes through equipment standing out in the cold, this part of the system requires additional protection against freezing.

Bureaucracy tips the scales in favor of the monobloc

For years, the European Union has made sure that refrigerants used in air conditioners and heat pumps do not escape into the atmosphere without consequence, because many of them contribute significantly to the greenhouse effect. Rather than counting kilograms directly, their quantity is converted into what is known as a CO2 equivalent, a measure of how much a given gas harms the climate compared with carbon dioxide. The more CO2 equivalent in a single system, the more paperwork is required: a certified technician must be hired, regular leak checks are mandatory, and once a certain threshold is exceeded, the system must be entered in a central register.

Think of it like regulations on transporting goods: up to a certain small quantity, you don’t need any additional permits, but when you transport more, additional requirements, notifications and inspections start to apply. With split systems, the threshold for paperwork is low because the refrigerant flows through pipes throughout the house, so any leak happens where you live and the law takes a more cautious approach. For the popular R32 refrigerant, the limit is around 7.4 kilograms. For a monobloc, where the entire circuit is factory-sealed and leak-tight, and any leaking gas is released outside the building, the same threshold is twice as high, at around 14.8 kilograms. W practice, this means that some split systems come close to the lower limit and require additional paperwork, while a comparable monobloc often stays below it without any complications. Even so, as the market data above shows, ease of compliance alone does not determine the choice of most investors.

2027: When R32 Will No Longer Matter

However, this whole calculation involving thresholds and kilograms will soon change, in favor of a completely different refrigerant. From January 1, 2027, EU regulations prohibit placing new heat pumps on the market that use refrigerants with a high global warming potential, including R32. This applies to both monoblocs up to 50 kW and air-to-water splits up to 12 kW—in other words, practically the entire segment of interest to owners of single-family homes. W practice, the market is already switching to natural refrigerants, primarily propane, designated R290, which has a negligible impact on the climate and is not subject to the same quantity restrictions. When choosing a heat pump today, it's worth checking which refrigerant it uses, because this is a question of future servicing and spare-parts availability over the next decade, not just current regulations.

Protecting a monobloc from freezing

A monobloc has one weakness to keep in mind: all the water in the system, not just the refrigerant, passes through the unit outside in freezing temperatures. If the power were to go out in the middle of a severe winter, the water in that part of the system could freeze and rupture the heat exchanger. That's why these systems use a mechanical antifreeze valve, which operates purely on temperature, without electricity or a controller, releasing a small amount of water before freezing occurs.

If you want the shortest possible installation time, fewer formalities, and are comfortable with an additional antifreeze valve as part of the installation, a monobloc will be the simpler choice, especially at lower and medium capacities. If, on the other hand, you're planning a larger installation, want all the heating water to remain safely inside the house without additional frost protection, or have an installer who is well-versed in working with refrigerants, a split remains the choice made by the vast majority of the Polish market, despite the additional formalities involved.

What a heat pump requires of the installation

Manufacturers like to present the unit itself as a complete solution, but that’s only part of the story. For a heat pump to operate reliably and efficiently, the rest of the system must be properly prepared. Three elements are especially important: the minimum water flow through the heat exchanger, a sufficiently large buffer tank to stabilize the unit’s operation, and hydraulic separation when a home has more than one heating circuit with different characteristics, such as radiators and underfloor heating running at the same time.

Flow errors and compressor cycling

If these requirements aren’t met, two problems tend to arise. The first is flow errors, which indicate that not enough water is passing through the heat exchanger to safely remove heat from the compressor. The second is compressor cycling, where the compressor repeatedly switches on and off at short intervals instead of running smoothly for longer periods. Both problems have the same underlying cause: the factory-installed pump inside the heat pump unit is designed to overcome the resistance of the unit itself, not of an entire, extensive installation with long underfloor heating loops. This is where an additional, properly selected pump group and manifolds can help, supporting flow where the heat pump alone can no longer cope.

Do you need to replace old radiators?

Old radiators are one of the most common reasons people rule out getting a heat pump for their home, and in most cases, there’s no need to worry. Radiators deliver heat more intensely the higher the temperature of the water supplying them, but that doesn’t mean they stop heating when the temperature is lower. It simply means they need to be larger or run for longer to deliver the same amount of heat. A home that’s been upgraded with new windows and insulation loses much less heat than before, so the same old radiators, supplied with lower-temperature water, are enough to maintain comfort.

COP, SCOP and actual bills

Manufacturers like to quote the COP, or the ratio of heat output to electricity consumed, measured at one specific operating point, for example with an air temperature of plus seven degrees and heating water at thirty-five degrees. The problem is that conditions in Poland are different for most of the heating season, so COP alone says little about actual bills. A better indicator is SCOP, or average seasonal efficiency, which takes changing weather throughout the year into account.

The German research institute Fraunhofer ISE monitored 77 systems in real-world operation for several years and obtained results worth knowing before buying: air-to-water heat pumps achieved an average SCOP of 3.4, ranging from 2.6 to 5.4 depending on the specific installation and home, while ground-source heat pumps averaged 4.3. The wide range of results clearly shows that the brand and model of the unit are not everything. The same heat pump, in a well-designed system with adequate flow and a flow temperature matched to the building’s actual heat losses, can achieve a result close to the upper end of the range rather than the lower end.

Dambat – a trusted manufacturer of pumps and hydrotechnical equipment with quality certifications.

Frequently asked questions

What is a split heat pump?

This is a system in which refrigerant flows through pipes between the outdoor and indoor units, so some of it is inside the home. W a monobloc, the entire refrigerant circuit is sealed at the factory inside the outdoor unit, and only water enters the home.

Why does a monobloc require less paperwork than a split system?

EU refrigerant regulations set a lower refrigerant charge threshold without additional formalities for split systems, because any leak would occur inside the home. For monobloc systems, where a leak would occur outside the building, the same threshold is twice as high, which means less paperwork in practice for typical installations.

Will R32 heat pumps disappear from the market in 2027?

From January 1, 2027, new heat pumps using refrigerants with a high global warming potential, including R32, may no longer be placed on the market in the power segment typical for single-family homes. The market is already shifting to natural refrigerants, primarily propane R290.

Can old radiators be used with a heat pump?

Usually, yes, especially after a building has been thermally upgraded. Radiators deliver less heat per unit of time at a lower flow temperature, but since the home loses less heat than before, the same radiator surface area is usually enough to maintain comfort.

What is the difference between COP and SCOP?

COP is the efficiency measured at one specific operating point, for example at a given air and water temperature. SCOP averages efficiency over the entire heating season, taking changing weather into account, so it better reflects real annual energy consumption.

Why does a heat pump short-cycle, turning on and off at short intervals?

The most common cause is insufficient water flow through the system for the unit’s capacity. This often results from the lack of an additional circulation pump to support the built-in pump in the unit, or from an undersized buffer tank to stabilize system operation.

 