Description
Quick reply
The IBO MGB 3 bar / MGB 6 bar safety group is a complete device for installation with an expansion vessel, designed to control and effectively protect heating installations against excessive pressure increases, equipped with a pressure gauge, automatic air vent and safety valve, mounted on a steel wall strip.
For whom
- Heating system installers - quick and safe installation of the complete IBO MGB 3 bar / MGB 6 bar safety group without the need to select separate safety elements.
- Boiler room servicing companies - easy control of the installation condition thanks to an integrated pressure gauge and simple procedures for periodic inspections and tests of the safety valve.
- Designers of central heating installations - reliable protection of boilers, heat pumps and other heat sources, with the option of selecting a 3 bar or 6 bar version according to the installation requirements.
- Owners of single-family houses and small buildings - reliable protection of the heating system against overheating and overpressure, reducing the risk of failure and flooding of rooms.
- Distributors and installation wholesalers - a branded IBO product from Dambat, a manufacturer of pumps and hydrotechnical equipment, facilitating the construction of a standard offer of security for boiler rooms.
Application
- Protection of central heating installations with boilers and heat pumps that require maintaining safe working pressure and the possibility of connecting an expansion vessel.
- Use in small and medium-sized water boiler rooms, where constant pressure monitoring using a manometer and automatic system venting are necessary.
- Heating installations with glycol solution (up to 50%), requiring resistance of the IBO MGB safety group to increased concentration of the agent and operating temperature up to 95°C.
- Systems with expansion vessels with a diameter of up to 320 mm and a weight of up to 45 kg, mounted directly on the safety group strip.
- Systems that require gravity discharge of the medium from the safety valve to the sewage system while maintaining visibility of the discharge.
The IBO MGB 3 bar / MGB 6 bar safety group for boilers and heat pumps provides comprehensive pressure protection of the heating installation.
Features, description and technical data
The IBO MGB 3 bar / MGB 6 bar safety group is a complete wall-mounted device, designed to work with an expansion vessel and a heat source, such as a boiler or heat pump, in central heating installations. Its main task is to control and protect the installation against excessive pressure increase by using a safety valve with a setting lower than the maximum allowable pressure of the heat source, as well as current pressure reading from the manometer and automatic venting of the system.
The body of the safety group is made of CW614N brass, while the mounting strip is made of galvanized steel, attached to the wall with pins and screws, which provides stable support for an expansion vessel with a diameter of up to 320 mm and a load of up to 45 kg. The body has internal threaded connections for connecting the installation and the expansion vessel, a pressure gauge (range 0-4 bar or 0-10 bar), a 1/2" safety valve with a setting of 3 bar or 6 bar, and an automatic air vent with a foot valve.
The IBO MGB safety group is designed to operate at the maximum working pressure in accordance with the version (3 bar or 6 bar), maximum medium temperature up to 95°C and maximum glycol concentration up to 50%. The design elements were selected to enable gravity discharge of the medium from the safety valve into the sewage system while maintaining the visibility of the outflow and eliminating the risk of negative pressure due to the lack of a permanent connection to the sewage system.
During installation, the IBO MGB safety group should be installed as close to the heat source as possible, on the supply or return pipe, in a way that prevents it from being accidentally cut off with a valve and without any narrowing or additional cut-off valves between the device and the boiler or heat pump. It is required that the installation site ensures safe discharge of the liquid stream from the safety valve, without directing it to people staying nearby, and allows convenient access for service and periodic tightness checks.
The operation of the IBO MGB safety group includes periodic, approximately every 3 months, checking the tightness of the safety valve, vent and body, as well as testing the valve by turning the knob several times to remove any possible contamination. In the event of leaks from the vent, it is recommended to unscrew it, clean the interior and reinstall it, but any service work must be performed after the installation has been cooled and emptied of the medium and pressure by qualified personnel.
The IBO MGB safety group is subject to the Pressure Equipment Directive 2014/68/EU as a device designed in accordance with recognized engineering practice, therefore it is not CE marked and full instructions for use are available on the Dambat website in the instructions section. Dambat is a trusted manufacturer of pumps and hydrotechnical equipment with quality certificates, which confirms the high quality and reliability of the IBO MGB 3 bar / MGB 6 bar safety groups.
FAQ
What is the IBO MGB 3 bar / MGB 6 bar safety group used for?
The IBO MGB 3 bar / MGB 6 bar safety group is used to control the pressure and protect the heating installation against excessive pressure increases by using a safety valve, manometer and automatic air vent, simultaneously cooperating with the expansion vessel.
How to select the version of the IBO MGB security group for installation?
The IBO MGB safety group version should be selected so that the opening pressure of the safety valve (3 bar or 6 bar) is lower than the maximum allowable pressure of the heat source, in accordance with the recommendations of the boiler or heat pump manufacturer.
Where to install the IBO MGB safety group in the installation?
The IBO MGB safety group is installed as close to the heat source as possible, on the supply or return pipe, without any shut-off valves or narrowings between the group and the boiler, in a place that allows safe discharge of the medium from the safety valve.
What are the basic operating parameters of the IBO MGB security group?
The IBO MGB safety group operates at a maximum medium temperature of up to 95°C, allows glycol concentration up to 50%, supports expansion vessels with a diameter of up to 320 mm and a weight of up to 45 kg, and is equipped with a pressure gauge with a range of 0-4 bar or 0-10 bar.
How often should the IBO MGB safety group be serviced?
Maintenance of the IBO MGB safety group includes periodic inspections approximately every 3 months, during which the tightness of the elements is checked, the operation of the safety valve is tested by turning the knob several times, and, if necessary, the automatic air vent is cleaned, maintaining the safety rules for working with the system turned off and cooled down.
Where can you buy the IBO MGB 3 bar / MGB 6 bar safety group?
The IBO MGB 3 bar / MGB 6 bar safety group is available online from authorized IBO distributors and in stationary installation wholesalers cooperating with Dambat; It is worth checking the current offer of partner stores for details.
Is the IBO MGB security group available in online stores?
The IBO MGB 3 bar / MGB 6 bar safety group is standardly offered in online stores with installation products and on sales platforms cooperating with Dambat distributors, which allows for convenient purchase and delivery to your home or company.
- Lifting: m,
- Performance: l/min.,
- Suction capacity: m,
- Power: kW,
- Power supply: ,
- Frequency: Hz,
- Power consumption: Oh,
- Motor Speed: rpm ,
- Dimensions: mm
- Weight: kg,
Quick reply
The IBO MGB 3 bar / MGB 6 bar safety group is a complete device for installation with an expansion vessel, designed to control and effectively protect heating installations against excessive pressure increases, equipped with a pressure gauge, automatic air vent and safety valve, mounted on a steel wall strip.
For whom
- Heating system installers - quick and safe installation of the complete IBO MGB 3 bar / MGB 6 bar safety group without the need to select separate safety elements.
- Boiler room servicing companies - easy control of the installation condition thanks to an integrated pressure gauge and simple procedures for periodic inspections and tests of the safety valve.
- Designers of central heating installations - reliable protection of boilers, heat pumps and other heat sources, with the option of selecting a 3 bar or 6 bar version according to the installation requirements.
- Owners of single-family houses and small buildings - reliable protection of the heating system against overheating and overpressure, reducing the risk of failure and flooding of rooms.
- Distributors and installation wholesalers - a branded IBO product from Dambat, a manufacturer of pumps and hydrotechnical equipment, facilitating the construction of a standard offer of security for boiler rooms.
Application
- Protection of central heating installations with boilers and heat pumps that require maintaining safe working pressure and the possibility of connecting an expansion vessel.
- Use in small and medium-sized water boiler rooms, where constant pressure monitoring using a manometer and automatic system venting are necessary.
- Heating installations with glycol solution (up to 50%), requiring resistance of the IBO MGB safety group to increased concentration of the agent and operating temperature up to 95°C.
- Systems with expansion vessels with a diameter of up to 320 mm and a weight of up to 45 kg, mounted directly on the safety group strip.
- Systems that require gravity discharge of the medium from the safety valve to the sewage system while maintaining visibility of the discharge.
The IBO MGB 3 bar / MGB 6 bar safety group for boilers and heat pumps provides comprehensive pressure protection of the heating installation.
Features, description and technical data
The IBO MGB 3 bar / MGB 6 bar safety group is a complete wall-mounted device, designed to work with an expansion vessel and a heat source, such as a boiler or heat pump, in central heating installations. Its main task is to control and protect the installation against excessive pressure increase by using a safety valve with a setting lower than the maximum allowable pressure of the heat source, as well as current pressure reading from the manometer and automatic venting of the system.
The body of the safety group is made of CW614N brass, while the mounting strip is made of galvanized steel, attached to the wall with pins and screws, which provides stable support for an expansion vessel with a diameter of up to 320 mm and a load of up to 45 kg. The body has internal threaded connections for connecting the installation and the expansion vessel, a pressure gauge (range 0-4 bar or 0-10 bar), a 1/2" safety valve with a setting of 3 bar or 6 bar, and an automatic air vent with a foot valve.
The IBO MGB safety group is designed to operate at the maximum working pressure in accordance with the version (3 bar or 6 bar), maximum medium temperature up to 95°C and maximum glycol concentration up to 50%. The design elements were selected to enable gravity discharge of the medium from the safety valve into the sewage system while maintaining the visibility of the outflow and eliminating the risk of negative pressure due to the lack of a permanent connection to the sewage system.
During installation, the IBO MGB safety group should be installed as close to the heat source as possible, on the supply or return pipe, in a way that prevents it from being accidentally cut off with a valve and without any narrowing or additional cut-off valves between the device and the boiler or heat pump. It is required that the installation site ensures safe discharge of the liquid stream from the safety valve, without directing it to people staying nearby, and allows convenient access for service and periodic tightness checks.
The operation of the IBO MGB safety group includes periodic, approximately every 3 months, checking the tightness of the safety valve, vent and body, as well as testing the valve by turning the knob several times to remove any possible contamination. In the event of leaks from the vent, it is recommended to unscrew it, clean the interior and reinstall it, but any service work must be performed after the installation has been cooled and emptied of the medium and pressure by qualified personnel.
The IBO MGB safety group is subject to the Pressure Equipment Directive 2014/68/EU as a device designed in accordance with recognized engineering practice, therefore it is not CE marked and full instructions for use are available on the Dambat website in the instructions section. Dambat is a trusted manufacturer of pumps and hydrotechnical equipment with quality certificates, which confirms the high quality and reliability of the IBO MGB 3 bar / MGB 6 bar safety groups.
FAQ
What is the IBO MGB 3 bar / MGB 6 bar safety group used for?
The IBO MGB 3 bar / MGB 6 bar safety group is used to control the pressure and protect the heating installation against excessive pressure increases by using a safety valve, manometer and automatic air vent, simultaneously cooperating with the expansion vessel.
How to select the version of the IBO MGB security group for installation?
The IBO MGB safety group version should be selected so that the opening pressure of the safety valve (3 bar or 6 bar) is lower than the maximum allowable pressure of the heat source, in accordance with the recommendations of the boiler or heat pump manufacturer.
Where to install the IBO MGB safety group in the installation?
The IBO MGB safety group is installed as close to the heat source as possible, on the supply or return pipe, without any shut-off valves or narrowings between the group and the boiler, in a place that allows safe discharge of the medium from the safety valve.
What are the basic operating parameters of the IBO MGB security group?
The IBO MGB safety group operates at a maximum medium temperature of up to 95°C, allows glycol concentration up to 50%, supports expansion vessels with a diameter of up to 320 mm and a weight of up to 45 kg, and is equipped with a pressure gauge with a range of 0-4 bar or 0-10 bar.
How often should the IBO MGB safety group be serviced?
Maintenance of the IBO MGB safety group includes periodic inspections approximately every 3 months, during which the tightness of the elements is checked, the operation of the safety valve is tested by turning the knob several times, and, if necessary, the automatic air vent is cleaned, maintaining the safety rules for working with the system turned off and cooled down.
Where can you buy the IBO MGB 3 bar / MGB 6 bar safety group?
The IBO MGB 3 bar / MGB 6 bar safety group is available online from authorized IBO distributors and in stationary installation wholesalers cooperating with Dambat; It is worth checking the current offer of partner stores for details.
Is the IBO MGB security group available in online stores?
The IBO MGB 3 bar / MGB 6 bar safety group is standardly offered in online stores with installation products and on sales platforms cooperating with Dambat distributors, which allows for convenient purchase and delivery to your home or company.





