Complete domestic wastewater pumping station consisting of a tank, a three-phase sewage pump with an axial macerator system, and a local control system.
The supplied pumping station is ready for pump installation and commissioning. The tank is equipped with connection nozzles for connecting the sewage inlet and discharge lines. The pump can be easily installed in or removed from the tank together with the piping, thanks to the system cast-iron coupling.
The pumping station can be used to pump sewage from septic tanks, single-family homes, offices, and small industrial facilities. It can be used both to pump sewage into gravity manholes and into high-pressure pipelines (up to 1.5–2 bar).
The basic control system ensures automatic pump operation and provides optical and audible notification when the maximum sewage level in the tank is exceeded.
Tank:
- HDPE plastic
- Horizontal and vertical anti-buoyancy ribs
- Wall thickness: 6–8 mm
- Tank dimensions: 2100 mm × 800 mm
- Equipped with a stainless-steel support beam
- Rubber inlet opening seals
- Stainless-steel bolts, screws, washers, and nuts
Control system:
- Start float switch
- Overflow float switch indicating that the alarm level in the pumping station has been exceeded
- Thermal pump protection
- Optical and audible alarm system indicating pumping station overflow, powered by low-voltage 12 V with type B protection
- Residual-current protection
- Surface-mounted IP65 control cabinet
- Automatic-Off-Manual switch
- Phase failure and phase asymmetry sensor
- Transformer reducing the voltage to 12 V
Fittings:
- DN50 cast-iron check valve
- DN50 ball shut-off valve
- DN50 cast-iron coupling
- AISI 304 DN50 pipeline
- d63 discharge connection (fitting)
- d160 inlet connection (socket)
Pump:
- DRENO Grix 32-2/090 T, cast iron
- Pump with a stainless-steel cutting knife
- Three-phase, 0.9 kW, 10 m cable
- Head: 2–22 m
- Capacity: up to 0–10 m³/h
- Weight: 21.5 kg