Description
PANDA 25-60/130 – circulator pump
The PANDA circulator pump features a permanent-magnet motor and an electronic differential pressure controller that automatically adjusts performance to the installation’s actual demand. The control panel with a display of current energy consumption makes it easy to monitor the device’s operation, while the included set of union fittings and adapter allows the PANDA pump to be installed without purchasing additional accessories.
Who it is for
- Central-heating installers – quick installation thanks to the union fittings and adapter included in the kit, with no need to select additional connectors.
- Single-family homeowners – automatic performance control in AUTO mode reduces energy consumption without the need for manual adjustment.
- Heating-system managers using night mode – the constant-speed settings HS1–HS3 maintain consistent operating parameters during selected hours.
- Service technicians – the energy-consumption display on the control panel enables quick assessment of the pump’s operation without additional measurements.
Applications
The PANDA circulator pump is suitable for constant-temperature heating systems with variable flow and installations where the pipe temperature changes depending on boiler operating conditions. It also performs well in heating systems with night mode, where the constant-speed settings HS1–HS3 maintain predictable operating parameters during selected hours of the day.
In addition to domestic central heating and clean-water circulation, the PANDA circulator pump also supports air-conditioning installations and industrial circulation systems, where both operational stability and reduced electricity consumption are important. The 230 V power supply of the PANDA circulator pump allows connection to a standard household electrical outlet.
Features
The differential pressure controller in the PANDA pump operates in four modes: AUTO, in which the proportional pressure curve automatically adapts to the installation’s changing demand, and HS1, HS2, and HS3, which are constant-speed curves useful under stable operating conditions. The permanent-magnet motor ensures low power consumption even at the lowest setting, while the control panel on the side of the motor makes it easy to change the mode without removing the housing.
The 25-60/180 and 25-60/130 versions differ in the spacing between the connection ports, allowing the pump to be fitted to an existing installation without replacing a section of piping. The 25-40/180 version is suitable for smaller installations with lower head requirements while retaining the same operating modes and installation method as the other models in the series.
- Type: electronic circulator pump with automatic differential pressure control
- Number of operating modes: 4 (AUTO, HS1, HS2, HS3)
- Power supply: 1×230V, 50Hz
- Protection rating: IP44
- Insulation class: F
- Pumped liquid temperature range: 2–95°C
- Permitted ambient temperature: 0–40°C
- Max. pressure in the central heating system: 1 MPa
- Operating pump noise level: 43 dB(A)
- Port / union fitting diameter: 1½" / 1"
- Port spacing: 130 mm
- Included: complete set of union fittings with an adapter for connecting the cable
- Control panel with a display showing current power consumption
IBO – 24-month (2-year) manufacturer's warranty. Warranty and post-warranty service is provided by Dambat.
The PANDA circulation pump combines automatic operation adjustment with simple installation, reducing both installation time and ongoing electricity consumption.
Frequently asked questions
What is the PANDA circulation pump used for?
The PANDA circulation pump supports water circulation in domestic and industrial central heating, clean technical water circulation, and air-conditioning systems. Automatic differential-pressure regulation adjusts its operation to the system's changing demand throughout the heating season.
What is the difference between the PANDA 25-60/130 and PANDA 25-60/180?
Both models have identical hydraulic parameters and the same operating modes—the only difference is the spacing between the connection ports (130 mm in the 130 version and 180 mm in the 180 version). The choice depends on the distance between the existing ports in the system where the pump is installed.
How does the PANDA pump differ from IBO circulation pumps with manual speed adjustment?
Unlike pumps with a manual I/II/III switch, the PANDA pump in AUTO mode independently adjusts its output to the system's current demand, without the need for manual adjustment. In addition, the control panel displays the current electrical power consumption, allowing you to continuously assess the device's operation.
Are additional fittings required to install the PANDA pump?
No—the PANDA pump comes with a complete set of union fittings and an adapter for connecting the cable, allowing the device to be installed without selecting additional installation accessories.
How do the AUTO and HS1–HS3 operating modes work?
AUTO is the factory setting in which the PANDA pump operates on a proportional pressure curve, automatically adjusting its output to the needs of the system. HS1, HS2, and HS3 are constant-speed curves, useful in systems requiring repeatable, unchanging operating parameters.
What is the warranty on the PANDA circulation pump?
The PANDA circulation pump by IBO is covered by a 24-month (2-year) manufacturer's warranty. Warranty and post-warranty service is provided by Dambat.
- Power: 0.05 kW,
- Power supply: 1~230 V,
- Frequency: 50 Hz,
- Current draw: A,
- Motor speed: 2850 rpm,
- Dimensions: 130/132/142 mm
- Weight: 2.8 kg,
Download: Karta_PANDA.pdf
Download: GARAN_Prawny_obowiazek_zapewnienia_zgodnosci_towaru_z_umowa.pdf
PANDA 25-60/130 – circulator pump
The PANDA circulator pump features a permanent-magnet motor and an electronic differential pressure controller that automatically adjusts performance to the installation’s actual demand. The control panel with a display of current energy consumption makes it easy to monitor the device’s operation, while the included set of union fittings and adapter allows the PANDA pump to be installed without purchasing additional accessories.
Who it is for
- Central-heating installers – quick installation thanks to the union fittings and adapter included in the kit, with no need to select additional connectors.
- Single-family homeowners – automatic performance control in AUTO mode reduces energy consumption without the need for manual adjustment.
- Heating-system managers using night mode – the constant-speed settings HS1–HS3 maintain consistent operating parameters during selected hours.
- Service technicians – the energy-consumption display on the control panel enables quick assessment of the pump’s operation without additional measurements.
Applications
The PANDA circulator pump is suitable for constant-temperature heating systems with variable flow and installations where the pipe temperature changes depending on boiler operating conditions. It also performs well in heating systems with night mode, where the constant-speed settings HS1–HS3 maintain predictable operating parameters during selected hours of the day.
In addition to domestic central heating and clean-water circulation, the PANDA circulator pump also supports air-conditioning installations and industrial circulation systems, where both operational stability and reduced electricity consumption are important. The 230 V power supply of the PANDA circulator pump allows connection to a standard household electrical outlet.
Features
The differential pressure controller in the PANDA pump operates in four modes: AUTO, in which the proportional pressure curve automatically adapts to the installation’s changing demand, and HS1, HS2, and HS3, which are constant-speed curves useful under stable operating conditions. The permanent-magnet motor ensures low power consumption even at the lowest setting, while the control panel on the side of the motor makes it easy to change the mode without removing the housing.
The 25-60/180 and 25-60/130 versions differ in the spacing between the connection ports, allowing the pump to be fitted to an existing installation without replacing a section of piping. The 25-40/180 version is suitable for smaller installations with lower head requirements while retaining the same operating modes and installation method as the other models in the series.
- Type: electronic circulator pump with automatic differential pressure control
- Number of operating modes: 4 (AUTO, HS1, HS2, HS3)
- Power supply: 1×230V, 50Hz
- Protection rating: IP44
- Insulation class: F
- Pumped liquid temperature range: 2–95°C
- Permitted ambient temperature: 0–40°C
- Max. pressure in the central heating system: 1 MPa
- Operating pump noise level: 43 dB(A)
- Port / union fitting diameter: 1½" / 1"
- Port spacing: 130 mm
- Included: complete set of union fittings with an adapter for connecting the cable
- Control panel with a display showing current power consumption
IBO – 24-month (2-year) manufacturer's warranty. Warranty and post-warranty service is provided by Dambat.
The PANDA circulation pump combines automatic operation adjustment with simple installation, reducing both installation time and ongoing electricity consumption.
Frequently asked questions
What is the PANDA circulation pump used for?
The PANDA circulation pump supports water circulation in domestic and industrial central heating, clean technical water circulation, and air-conditioning systems. Automatic differential-pressure regulation adjusts its operation to the system's changing demand throughout the heating season.
What is the difference between the PANDA 25-60/130 and PANDA 25-60/180?
Both models have identical hydraulic parameters and the same operating modes—the only difference is the spacing between the connection ports (130 mm in the 130 version and 180 mm in the 180 version). The choice depends on the distance between the existing ports in the system where the pump is installed.
How does the PANDA pump differ from IBO circulation pumps with manual speed adjustment?
Unlike pumps with a manual I/II/III switch, the PANDA pump in AUTO mode independently adjusts its output to the system's current demand, without the need for manual adjustment. In addition, the control panel displays the current electrical power consumption, allowing you to continuously assess the device's operation.
Are additional fittings required to install the PANDA pump?
No—the PANDA pump comes with a complete set of union fittings and an adapter for connecting the cable, allowing the device to be installed without selecting additional installation accessories.
How do the AUTO and HS1–HS3 operating modes work?
AUTO is the factory setting in which the PANDA pump operates on a proportional pressure curve, automatically adjusting its output to the needs of the system. HS1, HS2, and HS3 are constant-speed curves, useful in systems requiring repeatable, unchanging operating parameters.
What is the warranty on the PANDA circulation pump?
The PANDA circulation pump by IBO is covered by a 24-month (2-year) manufacturer's warranty. Warranty and post-warranty service is provided by Dambat.