IBO-GL-TZ-125-40 wellhead
The IBO wellhead is a cover that hermetically seals the casing pipe of a deep well and routes the discharge pipe and the pump's power cable through it. Thanks to the gasket clamped onto the casing pipe, it protects the well from the ingress of contaminants and surface water. The series includes two installation variants—TW and TZ—in several sizes suited to typical well installations.
Who is it for?
- Well drillers and drilling companies—watertight closure of the borehole and secure suspension of the pump from the metal eye.
- Submersible pump installers—routing the PE pipe and cable through a single sealed passage.
- Owners of domestic wells—protecting water intakes from surface contamination.
- Service technicians and maintenance teams—simplified access to the pump and periodic inspection of the well installation.
Applications
The TZ wellhead is used to close the casing pipes of deep wells in which a pump suspended on a line operates. The discharge pipe exits through the head, and the power cable is also routed through it, while the entire assembly remains watertight thanks to compression seals. A well closed in this way is protected from surface water, groundwater, and foreign objects.
The tight closure also allows better use of the capacity of shallower wells—the vacuum that can form between the head and the pump assists water intake as the water level drops. The specific variant depends on the casing pipe diameter, PE pipe diameter, and cable thickness. The IBO TW/TZ wellhead is available in versions suited to 110 and 125 mm casing pipes.
Features of the TZ wellhead series
The body, base, and head cover are made of glass-fiber-reinforced polyamide (PA6+30GF), a material resistant to loads and the conditions inside the well. Sealing is provided by an EPDM ring, while the screws, nuts, and eye for suspending the pump are made of galvanized steel. Each head has a cable gland ensuring a watertight passage for the power cable and a passage for the PE pipe sealed with a gasket.
The series differ in their installation method. The TW series head is fitted inside the casing pipe, while the TZ series head is placed over the casing pipe from above; the TZ version is additionally equipped with a PE quick connector and a threaded link for suspending the pump. Regardless of the variant, the metal eye allows a submersible pump weighing up to 200 kg to be safely suspended.
- Type: well head (sealing casing pipe cover)
- Series: TZ (placed over the casing pipe)
- Body material: glass-fiber-reinforced polyamide (PA6+30GF)
- Seal: EPDM
- Pump suspension eye: galvanized steel
- Compatible casing pipe diameter: 125 mm
- PE pipe passage: 40 mm
- Cable pass-through diameter: 6–12 mm
- Max. load (pump suspension): 200 kg
IBO – 24-month (2-year) manufacturer's warranty. Dambat provides warranty and post-warranty service.
Dambat – a trusted manufacturer of pumps and hydrotechnical equipment with quality certificates.
Frequently asked questions (FAQ) – what is the TW / TZ well head used for?
What is a well head used for?
The well head hermetically seals the casing pipe of a deep well and guides the discharge pipe and pump cable through it. It protects the well from surface water, groundwater, and contaminants, while the metal eye allows a pump weighing up to 200 kg to be safely suspended.
What is the difference between the TW and TZ series?
The TW series well head is installed inside the casing pipe, while the TZ series well head is placed over the casing pipe from above. The TZ version additionally has a PE quick connector and a screw link for suspending the pump. The choice depends on how the casing pipe is finished in the particular well.
How do I choose the right well head size for my well?
Three parameters must be matched: the diameter of the casing pipe (110 or 125 mm), the diameter of the PE pipe leading to the pump (25, 32, 40, or 50 mm), and the diameter of the power cable (6–10 mm in the TW series, 6–12 mm in the TZ series). The model designation, e.g. IBO-GL-TW-125-40, indicates the series, well head diameter, and PE pipe diameter, respectively. If you have any doubts, please contact our technical department.
How do I install a well head?
The PE pipe is connected to the pump's discharge outlet and passed through the well head, while the cable is fed through the cable gland. The pump is suspended on a rope attached to the well head's eye or link, after which the well head is seated in or placed on the casing pipe and the screws are tightened. Installation should be carried out by a qualified installer with the power disconnected.
Is the well head covered by the manufacturer's warranty?
IBO – 24-month (2-year) manufacturer's warranty. Dambat provides warranty and post-warranty service.
Where can I buy an IBO TW / TZ well head?
As a manufacturer, we do not sell directly. IBO TW and TZ series well heads are available from our trade partners, plumbing wholesalers, and authorized online distributors.