Description
Quick answer
IBO GP PRO system manifolds are compact manifolds for heating circuits, designed to work with IBO GP PRO pump groups, enabling the rapid expansion of central heating systems while maintaining high efficiency, hydraulic order and easy servicing.
Who is it for?
- Heating system installers and service technicians – quick wall mounting of IBO GP PRO manifolds using the included brackets, with a constant 125 mm center-to-center distance and easy connection of pump groups.
- Heating system designers – flexible configuration of 2, 3, 4, 2+1 or 3+2 heating circuits, enabling the construction of complex systems using IBO GP PRO BO, 3D-S and 3D-T pump groups.
- Owners of single-family homes and small facilities – an organized, space-saving boiler room with a manifold rated up to 50 kW and convenient servicing and system expansion options.
- Contractors installing compact boiler rooms – an IBO GP PRO system product that helps speed up installation, standardize solutions and reduce the number of installation errors.
- Distributors and plumbing wholesalers – branded IBO GP PRO manifolds compatible with popular pump groups, creating a coherent system with Dambat’s product range.
Applications
- Water-based central heating systems in residential buildings and small commercial facilities where several heating circuits need to be separated using a single heat source.
- Boiler rooms with boilers or heat pumps, where IBO GP PRO manifolds work with pump groups to serve radiator, underfloor and mixed heating circuits.
- Systems rated up to 50 kW, with a maximum medium temperature of 110°C and a maximum operating pressure of 5 bar, using water or a fluid compatible with the technical data as the working medium.
- Systems where maintaining a constant 125 mm center-to-center distance is important for convenient connection of ready-made pump groups, along with a clear, serviceable pipe layout.
- Modernization of existing boiler rooms where an organized expansion of the number of heating circuits is required without significantly enlarging the room.
IBO GP PRO manifolds for IBO GP PRO pump groups enable the construction of multi-circuit heating systems in an organized, compact and easily serviceable manner.
Features, description and technical data
IBO GP PRO manifolds are system manifolds for 2, 3, 4, 2+1 and 3+2 heating circuits, designed to work with IBO GP PRO BO, 3D-S and 3D-T pump groups in central heating systems. They enable the rapid construction of systems with multiple circuits while occupying little space, maintaining a clear division between supply and return and the appropriate connection spacing for pump groups.
IBO GP PRO manifolds are rated up to 50 kW, with a maximum operating pressure of 5 bar and a maximum operating temperature of 110°C, corresponding to typical parameters of heating systems in residential buildings and small facilities. The manifolds operate with water as the working medium, while the upper and lower connections are 1 1/2" in size, with a 125 mm center-to-center distance and EPDM seals, facilitating leak-tight installation with pump groups.
The dimensions of IBO GP PRO manifolds depend on the number of circuits: uninsulated versions for 2, 3 and 4 circuits have approximate lengths of 450, 750 and 1050 mm respectively, with a constant height of 180 mm and width of 60 mm, while insulated versions have an increased width of 140 mm. This allows the manifolds to maintain a compact design while providing a clear arrangement of connection outlets and convenient pipe routing.
IBO GP PRO manifolds are wall-mounted using the mounting brackets supplied with the product, while ensuring that the entire system is level and stable. After securing the manifold body, the upper and lower 1 1/2" connections are hydraulically connected to the heating system using suitable EPDM seals, ensuring that all connections are leak-tight before starting the system.
The pump groups are then installed according to the manufacturer’s instructions, ensuring that the 125 mm center-to-center distance is maintained and that the supply and return outlets are assigned correctly. The system is then started up gradually, increasing the pressure and temperature while checking for any leaks. Regular maintenance includes an annual inspection of the EPDM seals and connection tightness, as well as cleaning the manifold surface if necessary. All work must be carried out with the system cooled to room temperature.
IBO GP PRO manifolds are designed in accordance with the requirements of the Pressure Equipment Directive 2014/68/EU, while the manufacturer, Dambat, provides detailed installation, operation and maintenance instructions forming an integral part of the sales agreement. Dambat is a trusted manufacturer of pumps and hydrotechnical equipment with quality certificates, which translates into the reliability and safe use of IBO GP PRO system manifolds in professional heating installations.
FAQ
What are IBO GP PRO manifolds used for?
IBO GP PRO manifolds are used to separate and organize several heating circuits in a central heating system, working with IBO GP PRO pump groups to serve different heating zones.
How do I choose an IBO GP PRO manifold for my system?
The selection of an IBO GP PRO manifold is based on the number of required heating circuits and a system capacity of up to 50 kW, while ensuring that the pressure and temperature parameters comply with the product’s technical data.
How should an IBO GP PRO manifold be installed correctly?
An IBO GP PRO manifold should be mounted on a stable wall using the supplied brackets, ensuring that it is level. The 1 1/2" connections and pump groups should then be connected while maintaining the 125 mm center-to-center distance.
What are the basic operating parameters of IBO GP PRO manifolds?
IBO GP PRO manifolds are rated up to 50 kW, with a maximum operating pressure of 5 bar, a maximum operating temperature of 110°C, upper and lower 1 1/2" connections and EPDM seals. The center-to-center distance is 125 mm.
How should IBO GP PRO manifolds be maintained during operation?
Maintenance of an IBO GP PRO manifold includes at least an annual inspection of the EPDM seals and connection tightness, carried out with the system cooled down, as well as periodic cleaning of the surface without using aggressive chemicals.
Where can I buy IBO GP PRO manifolds?
IBO GP PRO manifolds are available from authorized IBO distributors, plumbing wholesalers cooperating with Dambat and online stores offering IBO products.
Are IBO GP PRO manifolds available online?
IBO GP PRO manifolds can be purchased online from specialist plumbing stores and sales platforms offering IBO products, with delivery directly to your home or business.
- Power: kW,
- Power supply: ,
- Frequency: Hz,
- Current draw: A,
- Motor speed: rpm,
- Dimensions: mm
- Weight: kg,
Quick answer
IBO GP PRO system manifolds are compact manifolds for heating circuits, designed to work with IBO GP PRO pump groups, enabling the rapid expansion of central heating systems while maintaining high efficiency, hydraulic order and easy servicing.
Who is it for?
- Heating system installers and service technicians – quick wall mounting of IBO GP PRO manifolds using the included brackets, with a constant 125 mm center-to-center distance and easy connection of pump groups.
- Heating system designers – flexible configuration of 2, 3, 4, 2+1 or 3+2 heating circuits, enabling the construction of complex systems using IBO GP PRO BO, 3D-S and 3D-T pump groups.
- Owners of single-family homes and small facilities – an organized, space-saving boiler room with a manifold rated up to 50 kW and convenient servicing and system expansion options.
- Contractors installing compact boiler rooms – an IBO GP PRO system product that helps speed up installation, standardize solutions and reduce the number of installation errors.
- Distributors and plumbing wholesalers – branded IBO GP PRO manifolds compatible with popular pump groups, creating a coherent system with Dambat’s product range.
Applications
- Water-based central heating systems in residential buildings and small commercial facilities where several heating circuits need to be separated using a single heat source.
- Boiler rooms with boilers or heat pumps, where IBO GP PRO manifolds work with pump groups to serve radiator, underfloor and mixed heating circuits.
- Systems rated up to 50 kW, with a maximum medium temperature of 110°C and a maximum operating pressure of 5 bar, using water or a fluid compatible with the technical data as the working medium.
- Systems where maintaining a constant 125 mm center-to-center distance is important for convenient connection of ready-made pump groups, along with a clear, serviceable pipe layout.
- Modernization of existing boiler rooms where an organized expansion of the number of heating circuits is required without significantly enlarging the room.
IBO GP PRO manifolds for IBO GP PRO pump groups enable the construction of multi-circuit heating systems in an organized, compact and easily serviceable manner.
Features, description and technical data
IBO GP PRO manifolds are system manifolds for 2, 3, 4, 2+1 and 3+2 heating circuits, designed to work with IBO GP PRO BO, 3D-S and 3D-T pump groups in central heating systems. They enable the rapid construction of systems with multiple circuits while occupying little space, maintaining a clear division between supply and return and the appropriate connection spacing for pump groups.
IBO GP PRO manifolds are rated up to 50 kW, with a maximum operating pressure of 5 bar and a maximum operating temperature of 110°C, corresponding to typical parameters of heating systems in residential buildings and small facilities. The manifolds operate with water as the working medium, while the upper and lower connections are 1 1/2" in size, with a 125 mm center-to-center distance and EPDM seals, facilitating leak-tight installation with pump groups.
The dimensions of IBO GP PRO manifolds depend on the number of circuits: uninsulated versions for 2, 3 and 4 circuits have approximate lengths of 450, 750 and 1050 mm respectively, with a constant height of 180 mm and width of 60 mm, while insulated versions have an increased width of 140 mm. This allows the manifolds to maintain a compact design while providing a clear arrangement of connection outlets and convenient pipe routing.
IBO GP PRO manifolds are wall-mounted using the mounting brackets supplied with the product, while ensuring that the entire system is level and stable. After securing the manifold body, the upper and lower 1 1/2" connections are hydraulically connected to the heating system using suitable EPDM seals, ensuring that all connections are leak-tight before starting the system.
The pump groups are then installed according to the manufacturer’s instructions, ensuring that the 125 mm center-to-center distance is maintained and that the supply and return outlets are assigned correctly. The system is then started up gradually, increasing the pressure and temperature while checking for any leaks. Regular maintenance includes an annual inspection of the EPDM seals and connection tightness, as well as cleaning the manifold surface if necessary. All work must be carried out with the system cooled to room temperature.
IBO GP PRO manifolds are designed in accordance with the requirements of the Pressure Equipment Directive 2014/68/EU, while the manufacturer, Dambat, provides detailed installation, operation and maintenance instructions forming an integral part of the sales agreement. Dambat is a trusted manufacturer of pumps and hydrotechnical equipment with quality certificates, which translates into the reliability and safe use of IBO GP PRO system manifolds in professional heating installations.
FAQ
What are IBO GP PRO manifolds used for?
IBO GP PRO manifolds are used to separate and organize several heating circuits in a central heating system, working with IBO GP PRO pump groups to serve different heating zones.
How do I choose an IBO GP PRO manifold for my system?
The selection of an IBO GP PRO manifold is based on the number of required heating circuits and a system capacity of up to 50 kW, while ensuring that the pressure and temperature parameters comply with the product’s technical data.
How should an IBO GP PRO manifold be installed correctly?
An IBO GP PRO manifold should be mounted on a stable wall using the supplied brackets, ensuring that it is level. The 1 1/2" connections and pump groups should then be connected while maintaining the 125 mm center-to-center distance.
What are the basic operating parameters of IBO GP PRO manifolds?
IBO GP PRO manifolds are rated up to 50 kW, with a maximum operating pressure of 5 bar, a maximum operating temperature of 110°C, upper and lower 1 1/2" connections and EPDM seals. The center-to-center distance is 125 mm.
How should IBO GP PRO manifolds be maintained during operation?
Maintenance of an IBO GP PRO manifold includes at least an annual inspection of the EPDM seals and connection tightness, carried out with the system cooled down, as well as periodic cleaning of the surface without using aggressive chemicals.
Where can I buy IBO GP PRO manifolds?
IBO GP PRO manifolds are available from authorized IBO distributors, plumbing wholesalers cooperating with Dambat and online stores offering IBO products.
Are IBO GP PRO manifolds available online?
IBO GP PRO manifolds can be purchased online from specialist plumbing stores and sales platforms offering IBO products, with delivery directly to your home or business.


