The S-150 is designed to control a central heating water circulation pump. The controller switches on the pump when the temperature exceeds the set value and switches it off if the temperature falls below the set switch-off temperature. This prevents the pump from running unnecessarily, saving electricity (depending on how intensively the boiler is used, savings can reach up to 60%) and extending the pump’s service life.
This increases its reliability and reduces operating costs. Both the switch-on and switch-off temperatures can be set within the range of 0˚C–99˚C.
Hysteresis has been replaced with the option to freely set the switch-off temperature.
Example: Set temperature 34˚C (lower display), switch-off temperature 31˚C. If the sensor temperature reaches 34˚C, the pump will switch on at 34˚C and run until the sensor temperature drops to 31˚C, at which point the controller will switch off the pump.
The S-150 central heating pump controller is equipped with 2 LED displays. The upper display shows the current temperature measured by the sensor by default, while the lower display shows the switch-off temperature. The MENU button switches the controller to preview and setting mode for the switch-off and switch-on temperatures, as well as the anti-stop function.
Thermostat function
The controller also has a built-in thermostat function. You can set a temperature at which the controller will switch off the controlled devices, then switch them back on once the temperature drops to the desired value.
Anti-freeze function
The controller is equipped with an ANTI-FREEZE function, which starts the pump when the ambient temperature drops below 5˚C to prevent freezing.
TECHNICAL DATA
- Temperature control range (set temperature): 0°C–99°C,
- Supply voltage: 230 V / 50 Hz ± 10%,
- Power consumption: < 5 W,
- Operating temperature: -10°C–40°C,
- Temperature sensor: Resistive,
- Sensor cable length: ~ 1 m,
- Mains cable length ~ 1 m,
- Pump power cable length: ~ 1 m,
- Output: 230 V / 50 Hz,
- Maximum output load current: pump 6A (resistive load)