Due to the available dimensions, the housings are compatible with most standard cartridges. The cartridges that can be used with our housings include:
- Mechanical cartridges: foam and string-wound,
- reusable mechanical cartridges: mesh,
- active cartridges: carbon block, granular activated carbon, water-softening, and ceramic.
ADVANTAGES
- Housing made of reinforced polypropylene,
- Two O-rings ensuring a watertight seal,
- Transparent housing allowing visual assessment of contamination,
- Max. pressure: 6 bar,
- Temperature range: 2–30°C.
To ensure proper filter operation and prevent damage, the following conditions must be met:
- Operating pressure in the system: 0.2–0.6 MPa (2–6 bar).
- Water hardness: Recommended value below 500 mg CaCO₃/l.
- Iron and manganese content: Maximum 0.2 mg/l of iron and 0.05 mg/l of manganese.
- Water pH: 5.5 to 9.
- Filtered water temperature: +2°C to +30°C.
- The water must not contain large amounts of mechanical sediment, sand, or silt. In such cases, a pre-filter is required.