Pompy IBO Dambat – obiegowe, hydroforowe, głębinowe

Dambat is a Polish manufacturer of modern water and hydrophore pumps and sewage pumping equipment, cooperating with, among others, with brands IBO i IPRO, formerly also known as IQ PR. The offer includes water pumps for heating installations, domestic hot water, hydrophore systems, sewage pumping stations and industrial applications, which allows installers and plumbers to select complete, consistent solutions for almost any application.

Types of water pumps in the Dambat offer

Professional water pumps Dambat include a wide range of devices: submersible pumps, hydrophore pumps, dirty water pumps, sewage pumps, circulation pumps and various types industrial pumps. The range is designed with demanding home and commercial installations in mind, so the installer can select both efficient septic tank pumps with a grinder and energy-saving ones central heating pumps for heating systems.

In everyday language there are imprecise terms such as "central heating pumps" or "furnace pumps", but the correct industry nomenclature is circulation pumps or central heating circulation pump, which are offered in many IBO brand variants. The phrase "heating pumps" is also sometimes confused with other products, while Dambat emphasizes clear terminology to facilitate the selection of the appropriate one. water circulation pumps for a specific installation.

IBO circulation and circulation pumps

The group of products for heating installations and domestic hot water includes: IBO circulation pumps, including models such as central heating circulation pump IBO, electronic circulation pump and classic three-stage structures. Installers can select a pump to suit the parameters of a specific system, paying attention to lifting height, efficiency, energy class and the possibility of cooperation with boiler automation.

The question often arises whether it will work better in the installation electronic or regular circulation pump – modern IBO electronic pumps, such as the line IBO BETA 2 25-60, ensure smooth modulation of performance, lower energy consumption and quieter operation compared to standard three-stage pumps. Small ones are also available circulation pumps for hot water, e.g. IBO circulation pump, designed to provide immediate access to hot water at consumption points.

Diagnostics and operation of the central heating pump

Correct operation central heating pumps requires proper assembly and regular operation control, because assembly errors may result in noise or premature wear of the bearings. Correct installation of the central heating pump includes placing the shaft in a horizontal plane, ensuring the appropriate amount of water in the installation and correctly setting the pump speed to avoid cavitation and unnecessary overload.

Typical symptoms of wear of the central heating circulation pump this means noisy operation, vibrations, loss of efficiency and problems with heating distant radiators, which may indicate a damaged pump. In such situations, it is worth checking whether the circulation pump is working, paying attention to engine operation, rotor rotation and the condition of the circulation pump's vent screw, which is used to remove air from the working chamber.

Venting and regulating the circulation pump

Correct venting the central heating pump is crucial for trouble-free operation because the presence of air in the system causes noise, loss of efficiency and excessive load on the bearings. Venting the central heating pump during operation is possible in many models thanks to the above-mentioned circulation pump vent screw - after slightly loosening it, it allows air and a small amount of water to escape.

The question often arises as to whether the central heating pump should run slowly or fast – the speed should be adapted to the characteristics of the installation and pressure losses, but too high a speed may cause noise, and too low a speed may cause underheating of the rooms. In case of doubt, the manufacturer's instructions, e.g. documentation, are a good point of reference IBO BETA 2 or IBO CPI 15-15, which contain setting recommendations.

Hydrophores, hydrophore pumps and tanks

Dambat offers complete hydrophore sets, covering hydrophore pumps, tanks and automation, intended to power single-family houses, farms and small service establishments. In practice, users look for such solutions under the headings: hydrophore, water boosters, hydrophore for water or hydrophore pump with engine, while the colloquial spelling "hudrofor" is incorrect and does not function as a product name.

In foreign language versions, terms are used hydrophore pump, hydrophore pump or hydrophore system, often found in descriptions of installations on ships ("hydrophore system in ship") and in technical materials regarding pressure vessels ("hydrophore tank", "hydrophore tank working principle", "was ist hydrophor", "hydrophoranlage"). In Russian, the terms "гидрофор", "гидрофор для дома", "гидрофор насос", "что такое" are used гидрофор", "гидрофор принцип работы", "принцип работы гидрофора", which refer to the same type of devices: pump + tank + automation sets for stabilizing the pressure in the water installation.

IBO submersible pumps – selection and protection

In the drilled well water supply segment, Dambat offers a wide range of devices such as IBO deep well pumps, including models 3 inch deep well pump, submersible pump for wells and submersible pump for a ring well. The key selection parameters are the depth of the water table, the diameter of the well, the required lifting height and the expected efficiency, which can be initially determined using tools such as selection of submersible pump calculator.

The offer also includes modern solutions, such as: submersible pump with a frequency converter, allowing you to maintain constant pressure in the installation and reduce energy consumption. Use is recommended for proper operation cooling jacket for a submersible pump when working in larger diameter tanks or wells and selecting the appropriate one inverter for a deep well pump or inverter to a deep well, including models intended for IBO pumps (e.g. IBO IVR 05, IBO IVR 10 line).

Pumps for clean, dirty and rainwater

It is popular in home and garden applications IBO water pump and others water pumps, intended for powering the installation, watering the garden or supplying sprinkler systems. They constitute a separate group rainwater pumps i pumps for rainwater tank, incl automatic rainwater pump, used in rainwater management and garden irrigation systems.

They are designed to work in difficult conditions dirty water pumps, incl dirty water pumps with a grinder and IBO dirty water pump, which are useful for pumping out flooded rooms, emptying septic tanks or technological tanks. In case of failure it is available repair of dirty water pumps and dedicated water pump parts and parts for dirty water pump, which makes it easier to service devices in the field.

Pumps for septic tanks, sewage and pumping stations

In the field of sewage and sewage, the offer includes, among others: septic tank pumps, septic tank pumps with a grinder, IBO septic tank pumps, as well as solutions from float switch, such as septic tank pump with grinder and float switch, adapted for continuous or intermittent operation. For demanding applications is available powerful septic tank pump with a grinder and permanent septic tank pump, intended for permanent installation in a manhole.

Installers can also choose sewage pumps with a grinder, sewage pumps, incl positive displacement pump for sewage, as well as complete systems such as pumping stations, sewage pumping stations, home sewage pumping stations i sewage pumping stations with a grinder. Dambat also functions as sewage pumping stations manufacturer, offering ready-made pump and pipe sets and accessories for the construction of small ones sewage pumping station i rainwater pumping station.

Submersible, sanitary and special pumps

The offer includes various submersible pumps, such as submersible pump IBO, submersible pump for septic tank and mini pump for dirty water, used for pumping out flooded rooms and emptying tanks. Additional equipment, e.g. submersible mixer, allows for better mixing and transport of thick sewage.

Specialized devices also include sanitary pumps (sanitary pumps), often installed as toilettenpump in German-language descriptions, ensuring pumping of sewage from toilets and sanitary utensils to a higher level. Foreign descriptions also include the terms "pompa pentru fosa septica" and "pumpa fosa septica", which refer to pumps for septic tanks, functionally similar to pumps with a septic tank grinder.

Pool pumps, for coolant and oil

In industrial applications, the following are used, among others: coolant pumps and electropumps for coolant, used in CNC machines, where they function under the following names CNC coolant pump or coolant pump for lathe. This type of devices ensures the circulation of the cooling and lubricating medium in the machining zone, which translates into the durability of the tools and the quality of the machined surface.

They constitute a separate group oil pumps, Pool pumps and devices such as condensate pump, condensate pump, condensate pump, used to drain condensate from air conditioning and condensing boilers. Thanks to this, the installer can buy pumps for clean water, sewage, swimming pools and industrial media in one place.

Pumps for pressure tests, underfloor heating and pressure boosting

For installation companies, Dambat also offers pressure test pumps, incl hand pumps for pressure tests, which are used to check the tightness of water and heating installations before putting them into operation. Concepts pressure test pump and leak test pump they refer to the same function - generating controlled overpressure in the installation.

In underfloor heating systems, appropriately selected heating is used underfloor pump, and in buildings with low pressure in the water supply network - pump to increase water pressure, incl a pump to increase the pressure of water from waterworks. In English-language documentation, you can find terms such as "DHW pump" (domestic hot water circulation pump) or "water pass" when describing the flow in installations, but Dambat mainly uses Polish nomenclature to facilitate the selection of devices for local installers.

Example models of IBO pumps

The product line includes many recognizable models such as IBO MHI 1300 INOX (often written as MHI 1300 INOX or MH 1300 INOX), HP INOX AUTO, IBO AJ 50/60, IBO NOVA, IBO MAGI 2, MAGI MAX, IBO STING and IBO KRAKEN 1800. It has gained particular popularity among pumps intended for sewage FURIOUS, including model IBO FURIATKA 1500, commonly referred to as Furiatka 1500 pump, designed to work in difficult operating conditions.

There are series for multi-stage sets used in hydrophore and irrigation plants IBO MULTI IP 1000 AUTO, IBO MULTI IP 1200 AUTO, as well as inverters IBO IVR 05, IBO IVR 10 (designations including IVR-10-030S, IVR-10), enabling the construction of advanced pressure maintenance systems. The documentation and technical data sheets also include markings such as: IBO 3TI20, IBO 3TI27, SWQ, M131, OHI, IBO OHI 25-40/180 manual, E-IBO 15-14, CPI 15-15, making it easier for installers to clearly identify devices.


How to choose an IBO circulation pump for a central heating installation?

Selection of the IBO circulation pump for the central heating installation. you should start by determining the power of the heat source, the length of the heating loops and the diameters of the pipes, as this affects the required flow and lifting height. The installer should pay attention to the pressure losses in the installation, including valves, manifolds and control elements, in order to correctly select the pump characteristics. Electronic models such as IBO BETA 2 or IBO CPI 15-15 enable modulation of performance and automatic adaptation to the current heat demand. In case of doubt, it is worth using the manufacturer's data sheets and selection calculators available in technical materials.

What should you pay attention to when using the IBO hydrophore?

The basis for the proper operation of the IBO pressure booster set is the appropriate initial pressure in the expansion tank and regular control of the pressure switch operation. Remember to protect the pump against dry running, especially in the case of intakes with variable water levels or high consumption in a short time. The installer should check the tightness of the suction system and the condition of the filters, because air in the system results in noisy operation and reduced efficiency. In case of irregularities, it is worth referring to the operating instructions of the hydrophore pump and adjusting the pressure switch settings to the installation requirements.

How to choose a submersible pump for a drilled well?

Selection of a submersible pump for a drilled well requires determining the depth of the water table, the diameter of the well and the required pressure at the highest point of the installation. On this basis, the total lifting height is calculated, taking into account pressure losses on fittings, filters and the length of the discharge pipe. It is also important to determine the maximum instantaneous and average water consumption in order to select the appropriate pump efficiency and engine power. If an inverter or automation that maintains constant pressure is used, the pump selection should be consulted with the manufacturer's documentation to ensure proper operation of the devices.

What solution should be used for sewage from a single-family house?

In the case of sewage disposal from a single-family house, when gravity flow into the sewage system is not possible, home sewage pumping stations are used. The selection of the set depends on the number and type of sanitary utensils, the depth of the tank and the distance to the sewage collector. In many cases, the optimal solution is a sewage pump with a grinder or a ready-made sewage pumping station with a grinder, which facilitates pumping the medium through a pipeline of small diameter. When selecting, pay attention to material resistance, engine power, lifting height and the presence of a float controlling the pump operation.

How to maintain high efficiency of the dirty water pump?

To maintain high efficiency of the dirty water pump, the condition of the impeller, working chamber and patency of the flow channels should be regularly checked. It is recommended to periodically rinse the pump with clean water after working in particularly contaminated sewage or slurries, which reduces the risk of deposits. In permanent installations, it is important to monitor the frequency of switching on and the operation of the float because it is blocked Float may cause the engine to overheat. If you notice a drop in performance, excessive noise or vibration, stop operating the device and verify its technical condition, using the manufacturer's service if necessary.

CiśnienieHydroforInoxKawitacjaNowościPompa do paliwaPompy do olejuPompy obiegowePompy powierzchniowePompy wielostopniowePompy z rozdrabniaczemWiadomości