Description
Quick reply
SKYLINE is an intelligent, compact pump with an inverter by IBO, designed to supply houses with clean water from wells and to increase the pressure from the water supply network. It provides constant pressure, quiet operation, energy saving and simple operation with two buttons.
For whom
- Single-family houses – stable water pressure even with several open draw-off points.
- Well users – safe operation thanks to dry-running protection and automatic diagnostics.
- Objects with low network pressure – automatic pressure stabilization with variable water supply parameters.
- Installers – quick startup without advanced programming, panel based on two buttons.
- Users expecting quiet operation – noise level up to 50 dB allows installation in utility rooms.
Application
- Power supply houses from your own shot – constant pressure and smooth start-up when working with a well.
- Pressure raising from the water supply network – automatic switching on when the supply pressure drops.
- Small water installations in residential buildings – compact dimensions facilitate installation in tight spaces.
- Installations with a risk of water hammer – the inverter eliminates sudden pressure surges.
The SKYLINE 165–260V inverter pump works wherever constant pressure and energy-saving operation of the installation are required.
Features, description and technical data
General characteristics
SKYLINE is an intelligent pump with a built-in frequency converter that maintains stable pressure in the installation regardless of the number of open receivers. The device operates in continuous S1 mode, and smooth speed regulation eliminates water hammer and reduces energy consumption. The pumps are equipped with a frequency converter, which guarantees constant pressure on all intake valves, smooth engine starts and lower power consumption than in the case of classic hydrophore sets. Pumps with a built-in frequency converter are modern and energy-saving devices, characterized by quiet operation, ease of installation and operation, and built-in protection against:
- dry running,
- water hammer,
- voltage drop or increase
- motor overload.
Construction
The pump consists of a hydraulic part (body, impeller, diffusers, stuffing box, non-return valve) and a control module with electronics and a pressure sensor. The fan housing and rotor used ensure effective cooling, and the console with an integrated control panel facilitates configuration.
Control panel
The panel allows you to set the pressure set with two buttons: increase and decrease. Current and set values are displayed simultaneously. LED diodes indicate: pump operation, leakage, water shortage, overload, temperature and voltage failures. Features include: reset, test, restoring factory settings and checking the medium temperature.
Scope of work and security
The device works with clean water at a temperature of 0-75°C and a pH of 6.5-8.5. The ambient temperature can be 0-50°C. The pump is intended for use in dry, ventilated and corrosive substances-free rooms.
Built-in protections include: protection against dry running, overload, under and over pressure, voltage spikes, freezing and overheating. Every 24 hours, the pump performs a short automatic switch-on to prevent the hydraulics from clogging.
Models and parameters
| Model | Motor power [W] | Max lifting [m] | Max. capacity [l/min] | Pressure adjustment range [bar] | Current consumption max. [A] |
|---|---|---|---|---|---|
| SKYLINE 1 | 370 | 40 | 65 | 1,5–4,0 | 2,8 |
| SKYLINE 2 | 750 | 55 | 93 | 1,5–5,5 | 5,0 |
| SKYLINE 3 | 1100 | 60 | 200 | 1,5–6,0 | 7,1 |
Connections and assembly
SKYLINE 1 and SKYLINE 2 are equipped with 1" connectors, and SKYLINE 3 with 1¼" connectors. The pump should be mounted horizontally on a stable surface, preferably on an anti-vibration layer. The suction pipe must be tight, with a minimum diameter of 1", with a slope towards the water table. Rubber suction hoses should not be used.
In drilled wells, it is recommended to install a non-return valve above the well filter. In circular wells - use of a suction basket min. 30 cm above the bottom. The electrical installation should have grounding and RCD and overcurrent protection.
Noise and comfort
The noise level of up to 50 dB allows installation in utility rooms, ensuring quiet operation and high comfort.
Warranty
The IBO SKYLINE pump is covered by a 24-month warranty.
Dambat – a trusted manufacturer of pumps and hydrotechnical equipment with quality certificates.
FAQ
Is the SKYLINE pump available online and in stores?
The SKYLINE pump is available both online and in stationary distribution points cooperating with the IBO brand. Many stores offer a full range of models, which makes it easier to select the version suitable for a specific installation. Online availability allows you to quickly compare parameters and prices, as well as check user opinions. At stationary points, you can count on additional technical support and inspection of the pump before purchasing. Installation wholesalers often also provide professional advice and the possibility of personal collection.
Where can I buy a SKYLINE pump?
The SKYLINE model can be purchased directly from IBO distributors and in authorized online stores. It is worth choosing official sales channels to be sure of the originality of the product and full warranty service. Installation wholesalers offer additional technical support and often carry all three models in the series. Purchasing from recommended partners also provides access to full documentation and necessary assembly accessories. Additionally, many sellers provide professional videos, diagrams and tips to facilitate installation.
What is the SKYLINE pump used for?
The SKYLINE pump is used to supply water installations with clean water from wells and to stabilize the pressure from the water supply network. Thanks to the built-in inverter, it ensures constant pressure regardless of the number of open taps. It is suitable for single-family houses, small residential buildings and installations requiring smooth flow regulation. Its intelligent electronics protect both the pump and the installation, minimizing the risk of hydraulic damage. This solution is for users who require quiet, stable and energy-saving operation.
How does SKYLINE differ from a traditional hydrophore?
Unlike a classic hydrophore, the SKYLINE pump maintains constant pressure thanks to the use of an inverter. This means that the device responds smoothly to changes in water demand, adjusting the engine speed, which translates into lower power consumption. The lack of sudden pressure changes increases the comfort of use and protects the installation against water hammer. Additionally, SKYLINE is much quieter and more compact than traditional pressure booster sets. It also has many more electronic protections that increase operational safety.
How to properly install the SKYLINE pump?
The SKYLINE pump should be installed in a horizontal position, on a stable and even surface, preferably using anti-vibration pads. The hydraulic installation must be tight, especially on the suction side, where flexible hoses should not be used. The suction pipe should have an appropriate slope and a diameter of at least 1" to ensure proper flow. It is very important to carry out the electrical installation in accordance with applicable standards, using RCD and overcurrent protection. It is recommended that the electrical installation be performed by a licensed electrician, as improper connection may lead to damage.
How to care for your SKYLINE pump?
The SKYLINE pump does not require advanced servicing, but it is recommended to regularly check the tightness of the installation and connections. During winter periods, special care should be taken to protect against freezing, as leaving water in the pump may lead to serious damage. If the pump is located in a room with a low temperature, it is worth considering additional insulation. During longer breaks in operation, the pump should be drained using the drain screw. Regularly observing the messages on the control panel will help you detect any irregularities early.
What security features does SKYLINE have?
The SKYLINE pump has an extensive set of safeguards that protect the device and installation against typical threats. This includes, among others: protection against dry running, engine overload, too low and high pressure and voltage surges. The electronic system also monitors the operating temperature and protects the device against overheating and freezing. If any irregularities are detected, the pump signals the problem using appropriate LEDs and error codes. This allows the user to react quickly and avoid costly failures.
What is the difference between the SKYLINE 1, SKYLINE 2 and SKYLINE 3 models?
Individual models differ in engine power, lifting height and maximum efficiency, which allows them to be adapted to various installations. SKYLINE 1 is the smallest model, intended for standard home installations with moderate water demand. SKYLINE 2 offers a higher lifting parameter and a larger flow, which is why it copes better in buildings with a larger number of receivers. SKYLINE 3 is the strongest variant, providing efficiency of up to 200 l/min, which allows it to handle more demanding installations. All models use the same electronics and inverter functions, differing only in hydraulic performance.
Can the SKYLINE pump operate with increased water temperature?
Yes, the SKYLINE pump can operate with water at a temperature of up to 75°C, which ensures great flexibility in its use. This means that it can work with installations in which water periodically reaches higher temperatures. However, please remember that high water temperature results in extended operation of thermal protection. Regularly checking working conditions will help avoid unnecessary interruptions in operation. The most important thing is that the ambient and installation temperatures do not exceed the values allowed in the documentation.
Is the SKYLINE pump suitable for drilled and circular wells?
The SKYLINE pump is suitable for both drilled and circular wells as long as the hydraulic parameters are within the allowable range. In drilled wells, it is recommended to use a check valve just above the well filter, which improves operational stability. In circular wells, it is necessary to use a suction basket placed at least 30 cm above the bottom to avoid sucking in contaminants. Thanks to its high suction capacity, the pump can cope with various types of intakes, provided it is installed correctly. The most important thing is to ensure tightness and adequate flow on the suction side.
- Lifting: 60.0 M,
- Efficiency: 200.0 l/min.,
- Suction capacity: M,
- Power: 1.1 kw,
- Power supply: ,
- Frequency: 50 Hz,
- Power consumption: 7.1 AND,
- Engine speed: 4000 rpm ,
- Dimensions: 410/235/510 mm
- Libra: 11.0 kg,
Quick reply
SKYLINE is an intelligent, compact pump with an inverter by IBO, designed to supply houses with clean water from wells and to increase the pressure from the water supply network. It provides constant pressure, quiet operation, energy saving and simple operation with two buttons.
For whom
- Single-family houses – stable water pressure even with several open draw-off points.
- Well users – safe operation thanks to dry-running protection and automatic diagnostics.
- Objects with low network pressure – automatic pressure stabilization with variable water supply parameters.
- Installers – quick startup without advanced programming, panel based on two buttons.
- Users expecting quiet operation – noise level up to 50 dB allows installation in utility rooms.
Application
- Power supply houses from your own shot – constant pressure and smooth start-up when working with a well.
- Pressure raising from the water supply network – automatic switching on when the supply pressure drops.
- Small water installations in residential buildings – compact dimensions facilitate installation in tight spaces.
- Installations with a risk of water hammer – the inverter eliminates sudden pressure surges.
The SKYLINE 165–260V inverter pump works wherever constant pressure and energy-saving operation of the installation are required.
Features, description and technical data
General characteristics
SKYLINE is an intelligent pump with a built-in frequency converter that maintains stable pressure in the installation regardless of the number of open receivers. The device operates in continuous S1 mode, and smooth speed regulation eliminates water hammer and reduces energy consumption. The pumps are equipped with a frequency converter, which guarantees constant pressure on all intake valves, smooth engine starts and lower power consumption than in the case of classic hydrophore sets. Pumps with a built-in frequency converter are modern and energy-saving devices, characterized by quiet operation, ease of installation and operation, and built-in protection against:
- dry running,
- water hammer,
- voltage drop or increase
- motor overload.
Construction
The pump consists of a hydraulic part (body, impeller, diffusers, stuffing box, non-return valve) and a control module with electronics and a pressure sensor. The fan housing and rotor used ensure effective cooling, and the console with an integrated control panel facilitates configuration.
Control panel
The panel allows you to set the pressure set with two buttons: increase and decrease. Current and set values are displayed simultaneously. LED diodes indicate: pump operation, leakage, water shortage, overload, temperature and voltage failures. Features include: reset, test, restoring factory settings and checking the medium temperature.
Scope of work and security
The device works with clean water at a temperature of 0-75°C and a pH of 6.5-8.5. The ambient temperature can be 0-50°C. The pump is intended for use in dry, ventilated and corrosive substances-free rooms.
Built-in protections include: protection against dry running, overload, under and over pressure, voltage spikes, freezing and overheating. Every 24 hours, the pump performs a short automatic switch-on to prevent the hydraulics from clogging.
Models and parameters
| Model | Motor power [W] | Max lifting [m] | Max. capacity [l/min] | Pressure adjustment range [bar] | Current consumption max. [A] |
|---|---|---|---|---|---|
| SKYLINE 1 | 370 | 40 | 65 | 1,5–4,0 | 2,8 |
| SKYLINE 2 | 750 | 55 | 93 | 1,5–5,5 | 5,0 |
| SKYLINE 3 | 1100 | 60 | 200 | 1,5–6,0 | 7,1 |
Connections and assembly
SKYLINE 1 and SKYLINE 2 are equipped with 1" connectors, and SKYLINE 3 with 1¼" connectors. The pump should be mounted horizontally on a stable surface, preferably on an anti-vibration layer. The suction pipe must be tight, with a minimum diameter of 1", with a slope towards the water table. Rubber suction hoses should not be used.
In drilled wells, it is recommended to install a non-return valve above the well filter. In circular wells - use of a suction basket min. 30 cm above the bottom. The electrical installation should have grounding and RCD and overcurrent protection.
Noise and comfort
The noise level of up to 50 dB allows installation in utility rooms, ensuring quiet operation and high comfort.
Warranty
The IBO SKYLINE pump is covered by a 24-month warranty.
Dambat – a trusted manufacturer of pumps and hydrotechnical equipment with quality certificates.
FAQ
Is the SKYLINE pump available online and in stores?
The SKYLINE pump is available both online and in stationary distribution points cooperating with the IBO brand. Many stores offer a full range of models, which makes it easier to select the version suitable for a specific installation. Online availability allows you to quickly compare parameters and prices, as well as check user opinions. At stationary points, you can count on additional technical support and inspection of the pump before purchasing. Installation wholesalers often also provide professional advice and the possibility of personal collection.
Where can I buy a SKYLINE pump?
The SKYLINE model can be purchased directly from IBO distributors and in authorized online stores. It is worth choosing official sales channels to be sure of the originality of the product and full warranty service. Installation wholesalers offer additional technical support and often carry all three models in the series. Purchasing from recommended partners also provides access to full documentation and necessary assembly accessories. Additionally, many sellers provide professional videos, diagrams and tips to facilitate installation.
What is the SKYLINE pump used for?
The SKYLINE pump is used to supply water installations with clean water from wells and to stabilize the pressure from the water supply network. Thanks to the built-in inverter, it ensures constant pressure regardless of the number of open taps. It is suitable for single-family houses, small residential buildings and installations requiring smooth flow regulation. Its intelligent electronics protect both the pump and the installation, minimizing the risk of hydraulic damage. This solution is for users who require quiet, stable and energy-saving operation.
How does SKYLINE differ from a traditional hydrophore?
Unlike a classic hydrophore, the SKYLINE pump maintains constant pressure thanks to the use of an inverter. This means that the device responds smoothly to changes in water demand, adjusting the engine speed, which translates into lower power consumption. The lack of sudden pressure changes increases the comfort of use and protects the installation against water hammer. Additionally, SKYLINE is much quieter and more compact than traditional pressure booster sets. It also has many more electronic protections that increase operational safety.
How to properly install the SKYLINE pump?
The SKYLINE pump should be installed in a horizontal position, on a stable and even surface, preferably using anti-vibration pads. The hydraulic installation must be tight, especially on the suction side, where flexible hoses should not be used. The suction pipe should have an appropriate slope and a diameter of at least 1" to ensure proper flow. It is very important to carry out the electrical installation in accordance with applicable standards, using RCD and overcurrent protection. It is recommended that the electrical installation be performed by a licensed electrician, as improper connection may lead to damage.
How to care for your SKYLINE pump?
The SKYLINE pump does not require advanced servicing, but it is recommended to regularly check the tightness of the installation and connections. During winter periods, special care should be taken to protect against freezing, as leaving water in the pump may lead to serious damage. If the pump is located in a room with a low temperature, it is worth considering additional insulation. During longer breaks in operation, the pump should be drained using the drain screw. Regularly observing the messages on the control panel will help you detect any irregularities early.
What security features does SKYLINE have?
The SKYLINE pump has an extensive set of safeguards that protect the device and installation against typical threats. This includes, among others: protection against dry running, engine overload, too low and high pressure and voltage surges. The electronic system also monitors the operating temperature and protects the device against overheating and freezing. If any irregularities are detected, the pump signals the problem using appropriate LEDs and error codes. This allows the user to react quickly and avoid costly failures.
What is the difference between the SKYLINE 1, SKYLINE 2 and SKYLINE 3 models?
Individual models differ in engine power, lifting height and maximum efficiency, which allows them to be adapted to various installations. SKYLINE 1 is the smallest model, intended for standard home installations with moderate water demand. SKYLINE 2 offers a higher lifting parameter and a larger flow, which is why it copes better in buildings with a larger number of receivers. SKYLINE 3 is the strongest variant, providing efficiency of up to 200 l/min, which allows it to handle more demanding installations. All models use the same electronics and inverter functions, differing only in hydraulic performance.
Can the SKYLINE pump operate with increased water temperature?
Yes, the SKYLINE pump can operate with water at a temperature of up to 75°C, which ensures great flexibility in its use. This means that it can work with installations in which water periodically reaches higher temperatures. However, please remember that high water temperature results in extended operation of thermal protection. Regularly checking working conditions will help avoid unnecessary interruptions in operation. The most important thing is that the ambient and installation temperatures do not exceed the values allowed in the documentation.
Is the SKYLINE pump suitable for drilled and circular wells?
The SKYLINE pump is suitable for both drilled and circular wells as long as the hydraulic parameters are within the allowable range. In drilled wells, it is recommended to use a check valve just above the well filter, which improves operational stability. In circular wells, it is necessary to use a suction basket placed at least 30 cm above the bottom to avoid sucking in contaminants. Thanks to its high suction capacity, the pump can cope with various types of intakes, provided it is installed correctly. The most important thing is to ensure tightness and adequate flow on the suction side.