PC-10P machine control of surface and deep pumps. Replaces the pressure switch and hydrophore tank. Unscrewing the tap gives a signal to the PC-10P machine, which launches the pump. Craction of the tap causes the PC-10P to turn off the pump. The machine, unlike the others, can operate with single phase pumps up to 2200 W, whose power consumption during operation is up to 16 A. The device has a dry provision function. When the water runs out in the well, the device turns off the pump. PC-10P has been equipped with a diameter of 1 ".
The machine is equipped with a 1 m long cable and a cable for connecting a 60 cm pump with a socket.
Parameters
- Sucking/pressure connector: 1 ",
- Built -in check valve,
- Protection against drywood,
- Built -in pressure gauge,
- Manual Reset button,
- Signaling diode Power supply Power,
- Diode signaling the ON pump operation,
- Diode signaling the failure of the Failure,
- Automatic restart
Technical data
- Supply voltage: 1 ~ 230 V,
- Protection degree: IP65,
- Maximum water temperature: 40 ° C,
- Switching pressure - 1.5-3 bar,
- Permissible maximum pressure in the system: 10 bar,
- Maximum current 16 A.