Intelligent Pump Controller - model IVR 02 M - is a control and safety device for direct connection of single-phase submersible pumps, surface pumps, submersible pumps, etc., with power from 0.37 kW to 1.5 kW (from 0.5 HP to 2 HP), maintaining a constant, set water pressure by changing the rotational speed of the pump motor. The IVR 02 M model (also known as an inverter or inverter) has many operating modes by adapting to various electrical installations.
FEATURES
- Energy efficiency: compared to the traditional method, the constant pressure water supply system with frequency converter saves energy by 30 - 60%.
- Long-term reliability of associated pumps: average torque and shaft wear are reduced due to a decrease in average rotational speed, which ensures a longer pump life.
- The built-in SOFT-START and soft stop function of the device allows you to eliminate water hammer (the water hammer effect means a sudden increase in pressure accompanying a quick stop or start of liquid flow).
- Comprehensive protection: the system has the most comprehensive protection technology for overcurrent, overvoltage, undervoltage, short circuit, blocked rotors, the ability to protect the pump against dry running without the need to install probes/sensors in the well.
- Possibility to control the operation of two pumps supplying the system.
APPLICATION
The IVR 02 M model will work well wherever there is a need to maintain constant water pressure in the installation and to control and protect a pump or a set of two pumps.
Expected typical usage:
- water supply from wells,
- irrigation of greenhouses, gardens and fields,
- collecting and using rainwater,
- water supply installation.
PARAMTERS
- Power: 0.37-1.5 kW,
- Power supply: 1~230V allowable fluctuations (160-260V),
- Rated output voltage: 1~230V,
- Rated output voltage of the second pump: 1~230 V / 50 Hz,
- Current: 12 A,
- Input frequency: 50/60 Hz,
- Output frequency: 20-50/60 Hz,
- Triggered response time in case of overload: 5 s - 5 min.,
- Pressure setting range: 1-9 bar,
- Triggered response time with open phase: < 5 s,
- Triggered response time on short circuit: < 0.1 s,
- Triggered response time on under/over voltage: < 5 s,
- Triggered response time for dry running: 6 s,
- Resume time after overload: 30 min.,
- Resume time for under/high voltage: 5 min.,
- Resumption time in dry running: 8 s, 1 min., 10 min., 30 min., 1 h, 2 h...,
- Overvoltage shutdown threshold: 270 V,
- Switch-off threshold at too low voltage 100 V,
- Fluid Level Transfer Distance: ≤ 1000m,
- Protection Features:
- Dry running,
- short circuit,
- overload,
- Overloaded pump,
- Sudden voltage surge,
- Sudden voltage drop
- Sudden increase in voltage
Basic technical characteristics
- Control characteristics:
- Dual flow control,
- pressure control,
- Control method:
- Flow control characteristics: Sample electrode pulse and flow switch,
- Pressure control characteristics: Pressure sensor 24 V, 4-20 mA.