The S-150 controller is intended for controlling the central heating water circuit pump. The controller's task is to switch on the pump if the temperature exceeds the set value and disable in the event of a decrease below the set level of the shutdown temperature. This prevents the pump from unnecessary, which saves electricity (savings depending on the degree of use of the oven reach up to 60%) and extends the life of the pump.
Thanks to this, its reliability increases and operating costs decrease. Both the switching and off temperature can be set in the 0˚C -99˚C range.
Hysteresis has been replaced by the possibility of any shutdown temperature setting.
Example: The set temperature 34˚C (bottom display), switching temperature 31˚C If the sensor temperature reaches 34˚C the pump turns on at 34˚C and works until the sensor temperature drops to 31˚C, then the controller will turn off the pump.
The CO S-150 pump controller is equipped with 2 LED displays. On the upper standard, the current temperature measured by the sensor is displayed, while the bottom shows the switching temperature. The menu button switches the controller to the preview mode and settings of the switching off, switching on and settings of anti-stop function.
Thermostat function
The controller also has a built -in thermostat function. It is possible to set the temperature when reaching which the controller will turn off the controlled devices, and then, after lowering the value to the desired value, will start the device.
Anti -splash function
The controller is equipped with an anti-freez function, thanks to which the controller at the time of a decrease in the ambient temperature below the 5˚C temperature, will start the pump so as not to freeze.
Technical data
- Temperature adjustment range (set temperature): 0 ° C -99 ° C,
- Supply voltage: 230 V / 50 Hz ± 10%,
- Power consumption: <5 W,
- Operating temperature: -10 ° C -40 ° C,
- Temperature sensor: resistance,
- Sensor cable length: ~ 1 m,
- The length of the network cable ~ 1 m,
- Pump power cord length: ~ 1 m,
- Exit: 230 V / 50 Hz,
- Exit load max. Pump 1A (foreign resistant)