PC-24 controller It is designed to control the pump by turning on and off the device. Turning depends on a decrease in water pressure in the water system below the minimum pressure set on the machine and the flow of flow in the pipe on which the PC-24 machine is installed. Disabling depends on the retention of water flow in the pipe.
The device turns on the pump when unscrewing the tap with water or opening the sprinklers, and turns off when the tap or sprinklers are closed. Has a function protection against dry -work - In the absence of water, the machine turns off the pump, protecting it from damage.
The device can be directly connected to pumps, whose engines do not download more than 30 and during operation. In addition, it protects the installation against flooding due to low leaks.
PC-24 It is intended for working with clean water without mechanical pollution.
Characteristics:
- Built -in pressure sensor
- Display showing the pressure in real -time installation
- Possibility to set the initial and final pressure as required
- Two modes of operation:
-
Mode 1 (DE1) - only setting the attachment pressure
-
Mode 2 (DE2) - setting the switching and switching pressure (tank required)
- Supply protection
- High pressure protection
- Automatic start after the operation of the drywood protection
- Vertical and horizontal assembly
- Automatic start for 10 seconds after 24 hours - a function protecting the pump against mechanical lock
Installation
At installation, pay attention to water flow direction - It is advisable to arrows on the connectors. If the pressure in the installation exceeds 10 bar, the device should be installed pressure reducer.
Connections with pipes are best sealed Teflon tape. The maximum height of the water column above the machine depends on the switching pressure set and cannot exceed the value corresponding to this pressure. The switching pressure should be selected according to the pump capabilities.
To make the PC-24 work properly, The pump must be able to create a pressure at least 1 bar higher than the switching pressure. The minimum difference between switching on and off is 1 bar.
ATTENTION: Due to the possible disturbance of flow, Do not mount the check valves between the pump and the controller. The device can only be used to cooperate with the pump.
Technical data
- Voltage / power frequency: AC 220–240 V / 50/60 Hz
- Max. Electricity: 30 (16) A
- The power of the controlled pump: 2.2 kW
- Protection degree: IP 65
- Water temperature: 40 ° C
- Permissible system pressure: 10 bar
- Entrance and output: 1 "
- Attaching pressure: 0.5 - 6.7 bar (mode 2), 0.8 - 6.7 bar (mode 1)
- Switching pressure: 0.8 - 7.0 bar
- Max. Pressure: 10 bar
FAQ-the most frequently asked questions about the PC-24 controller
What is the PC-24 controller for?
Controller PC-24 Automatically activates and stops the pump depending on the drop in water pressure and the appearance of flow in the installation. After opening the tap or sprinklers, the pump is turned on, and after closing them - off. The device also provides Protection against drywood, which protects the pump against damage in the absence of water.
Who is the PC-24 controller intended for?
The PC-24 is intended for home, garden and small installations who want to automate the work of the water pump. The device will work where there is a need for smooth regulation of the pump operation depending on the pressure and water flow, as well as protection against dry work.
What functions does the PC-24 controller have?
PC-24 has Built -in pressure sensor and a display showing its value in real time. Allows you to set the attachment and off pressure, offers two modes of operation (only switching on or switching off) and Automatic start after 24 hours of inactivity, which protects the pump from blocking. It protects against drywall and excessive pressure, and its assembly is possible vertically and level.
How to properly install the PC-24 controller?
During installation, you should be guided by water flow markings - arrows on the body. If the pressure in the installation exceeds 10 bar, the pressure reducer should be installed in front of the PC-24. Connections should be sealed with Teflon tape. Must not be mounted check valves between the pump and the controller. The pump should be able to reach a pressure of a minimum of 1 bar higher than the set pressure.
Where to buy iBO devices and pumps?