{"product_id":"zawor-zwrotny-kulowy-f-f-g1-1-2","title":"Clapet anti-retour à bille F\/F G1-1\/2\"","description":"\u003csection class=\"podzial_33_component composer_section grid_center grid_max_1920\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"section_big_wrapper tiny_mce img_anim grid_rwd_1440_element grid_resize\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"podzial_33\" data-mce-fragment=\"1\"\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"content padding_div top_padd\" data-mce-fragment=\"1\"\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan class=\"first_p\" data-mce-fragment=\"1\"\u003eClapet à filetage intérieur de 1½ pouce\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan class=\"first_p\" data-mce-fragment=\"1\"\u003eDescription du fonctionnement\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eLes clapets anti-retour à boule servent à empêcher le reflux dans une conduite. Le flux est arrêté par une boule qui repose dans le corps du clapet afin de former un joint d’étanchéité. Les clapets à boule sont conçus pour offrir un passage intégral, évitant ainsi le risque de blocage par des matières solides en suspension. En tournant dans les eaux usées qui s’écoulent, la boule se nettoie elle-même, ce qui rend très rares le colmatage du clapet et les défauts d’étanchéité. Les clapets anti-retour à boule sont recommandés pour les stations de pompage des eaux usées et des eaux pluviales, ainsi que pour tous les fluides susceptibles de contenir du sable, du gravier, des morceaux de tissu, des ficelles, etc.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eEn cas de blocage du clapet par des matières non conformes présentes dans les eaux usées, il suffit de dévisser les vis de fixation du couvercle d’inspection, de retirer la boule et de nettoyer l’intérieur du clapet. Ces opérations doivent toujours être effectuées lorsque l’alimentation électrique de la station de pompage est coupée. Avant de retirer le couvercle d’inspection, vérifiez que la vanne d’isolement située au-dessus du clapet anti-retour à boule est fermée, afin que les eaux usées revenant de la canalisation ne remplissent pas la cuve et ne gênent pas le travail du technicien de maintenance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"content padding_div top_padd\" data-mce-fragment=\"1\"\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan class=\"first_p\" data-mce-fragment=\"1\"\u003eRestrictions d’utilisation\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFluides non dangereux,\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePression maximale de 16 bar,\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePression minimale de 0,2 bar,\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eContre-pression minimale de 0,5 bar,\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePlage de températures de -10°C à 70°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan class=\"first_p\" data-mce-fragment=\"1\"\u003eApplication\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePompage des eaux usées,\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eStations de traitement,\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eStations d’épuration et chantiers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"content padding_div top_padd\" data-mce-fragment=\"1\"\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan class=\"first_p\" data-mce-fragment=\"1\"\u003eNormes\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eEN 13445\u003cbr data-mce-fragment=\"1\"\u003eEN 12334\u003cbr data-mce-fragment=\"1\"\u003eBrides PN10 – PN16\u003cbr data-mce-fragment=\"1\"\u003eFiletages ISO 228-1\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"edytor_text_component grid_max_1920 grid_center composer_section\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"edytor section_big_wrapper tiny_mce  grid_rwd_1440_element grid_resize\" data-mce-fragment=\"1\"\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan class=\"tiny_font_20\" data-mce-fragment=\"1\"\u003eEmplacement du clapet dans la station de pompage\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eLa fonction principale du clapet est d’empêcher le retour des eaux usées refoulées ; il est donc installé après la pompe, sur la conduite verticale de refoulement, avant les vannes d’isolement. Grâce à cette solution, en cas de nécessité de nettoyer ou de remplacer le clapet, il suffit de pomper les eaux usées et de fermer la vanne d’isolement. Les opérations sur le clapet seront ainsi beaucoup plus faciles.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSi le clapet anti-retour à boule est installé dans une station de pompage humide, où il existe un risque de contact avec les eaux usées, il est préférable de le placer au-dessus du niveau du fluide afin qu’il ne soit pas immergé. Lorsque le clapet est fréquemment en contact avec le fluide en raison des petites dimensions de la cuve, il est beaucoup plus sûr de le placer sous le niveau minimal des eaux usées, afin qu’il traverse le moins possible la zone de séparation entre les eaux usées et l’air. En l’absence d’accès à l’air, les processus de corrosion susceptibles de se produire dureront beaucoup plus longtemps que lors d’une immersion et d’un séchage continus.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eLorsque deux pompes ou plus fonctionnent dans une cuve, les clapets anti-retour à boule empêchent non seulement le reflux du liquide pompé hors de la cuve, mais également le retour du liquide refoulé par l’une des pompes. En l’absence de clapets anti-retour, lorsqu’une pompe refoule par une conduite verticale, les eaux usées reviennent par l’autre. Cela entraîne d’importantes pertes d’énergie et de temps, ainsi qu’un fonctionnement très inefficace du groupe de pompage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"DRENO","offers":[{"title":"Default Title","offer_id":47286850421079,"sku":"2000410","price":999999.99,"currency_code":"PLN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/2943\/3375\/files\/Zawor_zwrotny_kulowy_do_sciekow.jpg?v=1784884224","url":"https:\/\/dambat.pl\/fr\/products\/zawor-zwrotny-kulowy-f-f-g1-1-2","provider":"DAMBAT Jastrzębski S.K.A.","version":"1.0","type":"link"}