{"product_id":"zawor-zwrotny-kulowy-f-f-g2","title":"Kugelrückschlagventil F\/F G2“.","description":"\u003csection class=\"podzial_33_component composer_section grid_center grid_max_1920\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"section_big_wrapper tiny_mce img_anim grid_rwd_1440_element grid_resize\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"podzial_33\" data-mce-fragment=\"1\"\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"content padding_div top_padd\" data-mce-fragment=\"1\"\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan class=\"first_p\" data-mce-fragment=\"1\"\u003e2-Zoll-Innengewindeventil\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan class=\"first_p\" data-mce-fragment=\"1\"\u003eBeschreibung der Operation\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eKugelrückschlagventile werden verwendet, um einen Rückfluss in einer Rohrleitung zu verhindern. Der Durchfluss wird durch eine Kugel gestoppt, die dichtend im Ventilkörper sitzt. Kugelhähne sind so konzipiert, dass sie einen vollen Durchgang ermöglichen und so das Risiko einer Verstopfung durch Schwebstoffe vermeiden. Durch die Rotation im fließenden Abwasser hat die Kugel die Fähigkeit, sich selbst zu reinigen, sodass das Ventil nur sehr selten verstopft oder undicht wird. Kugelrückschlagventile werden für Abwasser- und Regenwasserpumpstationen und für alle Medien empfohlen, die sie mit sich führen können: Sand, Kies, Lumpenstücke, Schnüre usw.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWenn das Ventil durch einen abnormalen Abwassergehalt verstopft ist, lösen Sie einfach die Schrauben, mit denen der Inspektionsdeckel befestigt ist, entfernen Sie die Kugel und reinigen Sie den Inhalt des Ventils. Solche Arbeiten sollten immer bei ausgeschalteter Stromversorgung der Pumpstation durchgeführt werden. Bevor Sie den Inspektionsdeckel entfernen, prüfen Sie, ob der Absperrschieber über dem Kugelrückschlagventil geschlossen ist, damit das aus der Rohrleitung zurückfließende Abwasser den Tank nicht überschwemmt und die Arbeit des Ausdehnungsgefäßes behindert.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"content padding_div top_padd\" data-mce-fragment=\"1\"\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan class=\"first_p\" data-mce-fragment=\"1\"\u003eNutzungsbeschränkungen\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eHarmlose Flüssigkeiten\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMaximaler Druck 16 bar\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMindestdruck 0,2 bar\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMindestgegendruck 0,5 bar\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTemperaturbereich von -10 °C bis 70 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan class=\"first_p\" data-mce-fragment=\"1\"\u003eSchicksal\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAbwasser abpumpen,\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eReinigungsstationen,\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eKläranlagen und Baustellen.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"content padding_div top_padd\" data-mce-fragment=\"1\"\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan class=\"first_p\" data-mce-fragment=\"1\"\u003eNormen\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eEN 13445\u003cbr data-mce-fragment=\"1\"\u003eEN 12334\u003cbr data-mce-fragment=\"1\"\u003ePN10 – PN16 Flansche\u003cbr data-mce-fragment=\"1\"\u003eISO 228-1-Gewinde\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"edytor_text_component grid_max_1920 grid_center composer_section\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"edytor section_big_wrapper tiny_mce  grid_rwd_1440_element grid_resize\" data-mce-fragment=\"1\"\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan class=\"tiny_font_20\" data-mce-fragment=\"1\"\u003eVentilposition in der Pumpstation\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eDie Hauptaufgabe des Ventils besteht darin, den Rückfluss des gepumpten Abwassers zu verhindern. Deshalb platzieren wir es nach der Pumpe auf der Abflusssteigleitung und vor den Absperrventilen. Dank dieser Lösung genügt es, das Abwasser abzupumpen und das Ventil zu schließen, wenn das Ventil gereinigt oder ausgetauscht werden muss. Unter diesen Bedingungen wird das Arbeiten mit dem Ventil viel einfacher.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWenn das Kugelrückschlagventil in einer Nasspumpstation platziert wird, wo die Gefahr eines Kontakts mit Abwasser besteht, ist es am besten, es oberhalb des Mediumspiegels zu platzieren, damit es nicht überflutet wird. Wenn das Ventil aufgrund der geringen Abmessungen des Tanks häufig Kontakt mit dem Medium hat, ist es viel sicherer, es unter dem niedrigsten Abwasserspiegel zu platzieren, damit es möglichst wenig durch die Abwasserluftstelle gelangt. Bei fehlendem Luftzugang dauern eventuell auftretende Korrosionsprozesse wesentlich länger an als bei kontinuierlicher Flutung und Trocknung.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eBeim Betrieb von zwei oder mehr Pumpen in einem Tank verhindern Kugelrückschlagventile nicht nur den Rücklauf der Förderflüssigkeit aus dem Tank, sondern auch den Rücklauf der von einer der Pumpen geförderten Flüssigkeit. Wenn keine Rückschlagventile vorhanden sind und eine Pumpe durch das andere Abflussrohr pumpt, fließt das Abwasser zurück. Dies führt zu großen Energie- und Zeitverlusten und einem sehr ineffizienten Betrieb der Pumpeneinheit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"DRENO","offers":[{"title":"Default Title","offer_id":47286848946519,"sku":"2000413","price":999999.99,"currency_code":"PLN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/2943\/3375\/files\/Zawor_zwrotny-kulowy_do_sciekow_0c3e03f2-6954-4f42-b479-530687ce2556.jpg?v=1698935202","url":"https:\/\/dambat.pl\/de\/products\/kugelruckschlagventil-f-f-g2","provider":"DAMBAT Jastrzębski S.K.A.","version":"1.0","type":"link"}